Solution
• 1 UL (LOW state) = 1.6 mA and 1 UL (HIGH state) = 40 - A.
• The input loading factor (HIGH state) = 20 - A = 20/40 = 0.5 UL.
• The input loading factor (LOW state) = 0.1 mA = 0.1/1.6 = 1/16 UL
• The output loading factor (HIGH state) = 0.4 mA = 0.4/0.04 = 10 UL.
• The output loading factor (LOW state) = 4 mA = 4/1.6 = 2.5 UL.